• Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
  • Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
  • Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
  • Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
  • Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
  • Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves

Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves

Type: Water-Cooled
Cooling Method: Water-cooled
Selected Voltage: 380-415, 440, 460, 50/60Hz
Noise Level: Low
Application Fields: Factory, Hospital, Supermarket and So on
Certification: CE
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
WWXX
Condition
New
Air Tube Material
Galvanized Sheet
Corrosion Durability
General
Mounting
on The Ground
Lifetime
1-2 Year
Compressor
Bitzer/Hanbell/Fusheng
Electric Parts
Schneider
Refrigerant Valves
Emerson/Danfoss
Refrigerant
R22/R407c/R134A
Control
Siemens/Punp
Heat Exchanger
Shell and Tube Type
Transport Package
Plastic Film Wrapped
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
5000/Year

Product Description

Product Description

Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant ValvesGlycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves

* Performance values refer to the following conditions:
Condenser water inlet/outlet temperature: 30ºC/35ºC, evaporator water inlet/outlet temperature: 5ºC/-5ºC.
** Noise level measured in free field condition at distance of 1 meter.

Water temperature range -22C to 0C.
Shell and tube type condenser with adequate heat exchanging surface
Siemens PLC control, overall monitoring of unit running status
Refrigerant sight glass, to further monitor the refrigerant status
Refrigeration solenoid valve, to protect compressor when stopped
Refrigerant Low and high Pressure Gauges
Multi-protection devices to make sure the chiller and the equipment running safety.
Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves


Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves
Glycol Screw Type Water Cooled Chiller with Emerson/Danfoss Refrigerant Valves

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now