Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
  • Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
Find Similar Products

Basic Info.

Model NO.
AA
Type
Chiller
Air Tube Material
Galvanized Sheet
Corrosion Durability
General
Operating Voltage
380-415, 440, 460, 50/60Hz
Noise Level
Ordinary
Application Fields
Supermarket, Hospital, Pharmaceutical and Building
Mounting
Split
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
Usage
Commercial/Industrial
Cooling
Cooling Only or Heat Pump
Refrigerant
R22/R407c/R410A/R134A
Filter Type
Pre, Medium and HEPA(Optional)
Indoor Unit
Vertical and Horizontal Use
Compressor
Scroll Type
Transport Package
Standard Package Fit for Transportation
Specification
Color: white
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
10000PCS/Year

Packaging & Delivery

Package Size
1210.00cm * 520.00cm * 1080.00cm
Package Gross Weight
130.000kg

Product Description

Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
Ducted Split Unit


Cooling capacity 20kW ~ 104kW 

Product Description

11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.

Split installation, connected by means of flare/welding coupling.

Easy operation line controller:
  • Cooling/Heating/Fan/Auto
  • Timing On/Off
  • Error indication

Multi safety protection
  • High/low pressure protection
  • Time delay and antifreeze switch
  • Phase sequence relay
  • Current overload protection
  • Overheat protection
OPTIONAL
Additional electric heater on indoor unit
Additional heating coil on indoor unit


Technical Data
 
Mod.     20 25 32 36 42 48
Nominal cooling capacity* kW 19.5 24.8 31.2 35.6 41.3 47.4
Nominal heating capacity** kW 22.6 28.9 35.8 40.8 46.9 54.4
Connection              
Method / Flare Flare Flare Welding Welding Welding
Liquid pipe diameter ¢mm 9.52x2 12.7x2 12.7x2 15.88x1 15.88/12.7 15.88/12.7
Gas pipe diameter ¢mm 15.88x2 19.05x2 19.05x2 28x1 28/19.05 28/19.05
Power supply / 230V/3N/60Hz
OUTDOOR UNIT Compressor    
Qty/refrigerant circuit Nr. 2/2 2/2 2/2 1/1 2/2 2/2
Cooling power input* kW 7.2 9.3 11.8 12.8 15.1 17.9
Heating power input** kW 7.13 9.21 11.68 12.67 14.95 17.72
Energy adjustment % 50-100 50-100 50-100 0-100 40-60-100 33-66-100
Axial fans     
Quantity   Nr. 1 1 1 1 2 2
Airflow  m3/h 9400 9400 12500 14200 18800 18800
Sound pressure level*** dB(A) 67 67 68 70 71 71
Net weight kg 170 180 220 280 260 280
INDOOR UNIT Centrifugal fans              
Quantity Nr. 2 2 2 2 2 2
Airflow m3/h 3500 4500 5650 6450 7400 8550
ESP Pa 120 100 150 130 180 200
Sound pressure level*** dB(A) 64 64 66 66 68 68
Net weight kg 90 100 150 160 180 200
Additional electric heater**** kW 2×3 2×4 2×5 2×6 2×6 2×8
Additional heating coil**** kW 22.2 28.4 35.1 40.0 46.0 53.3
Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
**** Optional as request.
 
If you want more sizes, please contact us for details

Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit

Product Show

Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit

Projects

Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit


More Products
Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
Company View
Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split UnitDirect Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
Direct Expansion Air Cooled Chiller Split Rooftop Packaged Unit Top Discharge Condensing Unit / Horizontal Ducted Split Unit
FAQ

1.What is your advantages?
Customized is one of our advantages.

2.What is your trade term?
FOB Qingdao, China.

3.What is the delivery time?
About 25~30days to finish after got deposit or received original L/C.

4.What is the payment term?
30%TT as deposit + 70%TT before delivery or irrevocable L/C at sight.

5.What is your main products?
Water chiller, Rooftop packaged unit, Water source heat pump, Low ambient air source heat pump and Fan coil unit etc.

6.What is the warranty?
12 months after delivery or 18months commissioning, which comes first.

Send your message to this supplier