Industrial Glycol Water Chiller with Built in Water Pump

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Still deciding? Get samples of US$ 1673/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Industrial Glycol Water Chiller with Built in Water Pump
  • Industrial Glycol Water Chiller with Built in Water Pump
  • Industrial Glycol Water Chiller with Built in Water Pump
  • Industrial Glycol Water Chiller with Built in Water Pump
  • Industrial Glycol Water Chiller with Built in Water Pump
  • Industrial Glycol Water Chiller with Built in Water Pump
Find Similar Products

Basic Info.

Model NO.
AW()
Cooling Method
Air-cooled
Unit Structure
Integral
Selected Voltage
380V/50HZ
Compressor Number
2
Noise Level
Ultra Quiet
Certification
CE
Condition
New
Refrigerant
R410A/R407c/R134A/R32
Heat Exchanger
Phe/Tube in Tube
Compressor
DC Inverter/Fixed Speed
Fan Motor
Ec/AC
Optional
Heat Recovery, Free Cooling
Transport Package
Fumigation-Free Wood Packaging
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
5000sets/Year

Packaging & Delivery

Package Size
160.00cm * 90.00cm * 108.00cm
Package Gross Weight
270.000kg
Lead Time
25 days (1 - 5 Pieces)
To be negotiated ( > 5 Pieces)

Product Description

Industrial Glycol Water Chiller
Industrial Glycol Water Chiller with Built in Water Pump


Characteristics
 
Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents

Compressor
Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators

Axial fan
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, provided with a protective outlet grille

Evaporator
High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element (option) and differential pressure switch, factory insulated with flexible close cell material

Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins,100% fully quality tested; sub cooling circuit to prevent freezing at the base (optional); protected with metal grill

Desuperheater
High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material(optional)
 
Refrigerant circuit
Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, thermostatic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset . The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve
 
Water circuit
Built with air vent valve, water drain connection, and female-threaded hydraulic connectors
Water pump (8kW-30kW), differential pressure switch
Expansion tank (8kW-30kW)
 
Electric panel
Consists of:
Compressor contactor
Compressor protection breaker
Fan motor protection breaker
Control circuit protection breaker
Phase sequence relay (only for 3-phase)
Programmable microprocessor controller
 
Optional
Additional electric heater embedded in the coils for defrosting in low temperature ambient. It must be factory installed
Stainless steel covering
Remote condenser
 Tube in tube heat exchanger
Water circuit electric heater

Industrial Glycol Water Chiller with Built in Water Pump

Technical Data
  
Model   Unit 20 25 30 35 40 50
Cooling *  
Cooling capacity kW 21.5 24.8 30 35.6 41 50.6
Cooling input (without water pump) kW 8.2 9.03 9.39 13.2 15.02 18.8
EER / 2.62 2.75 3.19 2.7 2.73 2.69
Heating **  
Heating capacity kW 26.3 29 34 41.8 47.2 60
Heating input (without water pump) kW 8.7 9.23 9.43 14.3 15.57 20.45
COP / 3.02 3.14 3.61 2.92 3.03 2.93
Hermetic compressor  
Type /  
Quantity/ circuit / 2/2 2/2 2/2 2/2 2/2 2/2
Evaporator  
Type /  
Water flow m3/h 3.7 4.3 5.2 6.1 7.1 8.7
Water side pressure drop kPa 38 39 42 50 52 52
Water connection size mm DN40 DN40 DN40 DN40 DN40 DN40
Circulating pump  
Power input kW 0.75 0.75 0.92 --------- --------- -----------
Axial fans  
Quantity Nr. 1 1 1 2 2 2
Airflow m3/h 9000 9000 12580 17000 17000 22000
Overal dimension  
Length mm 1600 1600 1600 2000 2000 2000
Width mm 900 900 900 900 900 900
Height mm 1080 1080 1080 1080 1080 1080
Noise level *** dB(A) 66 66 68 70 70 70
Net weight kg 270 290 310 360 380 465

* Ambient temperature 35ºC; user side water in/out 12/7ºC.
** Ambient temperature 7ºC; user side water in/out 40/45ºC.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in an ideal field (fan side).

Industrial Glycol Water Chiller with Built in Water Pump


Why Choose Amrta?
Industrial Glycol Water Chiller with Built in Water Pump

Project
Industrial Glycol Water Chiller with Built in Water Pump

Ordering Process
Industrial Glycol Water Chiller with Built in Water Pump


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier