• Commercial Concealed Ducted Split Air Conditioning
  • Commercial Concealed Ducted Split Air Conditioning
  • Commercial Concealed Ducted Split Air Conditioning
  • Commercial Concealed Ducted Split Air Conditioning
  • Commercial Concealed Ducted Split Air Conditioning
  • Commercial Concealed Ducted Split Air Conditioning

Commercial Concealed Ducted Split Air Conditioning

Type: Central Air Conditioners
Capacity: 20kw~104kw
Usage: Room
Indoor Machine Noise: <23dB
Certification: CE
China Energy Efficiency Standard: Level 1
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AA()
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Condition
New
Refrigerant
R410A/R290/R32/R134A
Compressor
Scroll Type
Filter Type
Pre, Medium and HEPA(Optional)
Transport Package
Plastic Film Wrapped
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
1000PCS/Year

Product Description

Ducted Split Air Conditioner

Characteristics
11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.
Split installation, connected by means of flare/welding coupling.

Easy operation line controller:
• Cooling/Heating/Fan/Auto
• Error indication
• Timing On/Off
• Multi safety protection
• High/low pressure protection
• Overheat protection
• Current overload protection
• Phase sequence relay
• Time delay and antifreeze switch

Optional
• Additional electric heater on indoor unit
• Additional heating coil on indoor unit


Commercial Concealed Ducted Split Air Conditioning



Technical Data

Mod.     20 25 32 36 42 48
Nominal cooling capacity* kW 19.5 24.8 31.2 35.6 41.3 47.4
Nominal heating capacity** kW 22.6 28.9 35.8 40.8 46.9 54.4
Connection              
Method / Flare Flare Flare Welding Welding Welding
Liquid pipe diameter ¢mm 9.52x2 12.7x2 12.7x2 15.88x1 15.88/12.7 15.88/12.7
Gas pipe diameter ¢mm 15.88x2 19.05x2 19.05x2 28x1 28/19.05 28/19.05
Power supply / 230V/3N/60Hz
OUTDOOR UNIT Compressor    
Qty/refrigerant circuit Nr. 2/2 2/2 2/2 1/1 2/2 2/2
Cooling power input* kW 7.2 9.3 11.8 12.8 15.1 17.9
Heating power input** kW 7.13 9.21 11.68 12.67 14.95 17.72
Energy adjustment % 50-100 50-100 50-100 0-100 40-60-100 33-66-100
Axial fans     
Quantity   Nr. 1 1 1 1 2 2
Airflow  m3/h 9400 9400 12500 14200 18800 18800
Sound pressure level*** dB(A) 67 67 68 70 71 71
Net weight kg 170 180 220 280 260 280
INDOOR UNIT Centrifugal fans              
Quantity Nr. 2 2 2 2 2 2
Airflow m3/h 3500 4500 5650 6450 7400 8550
ESP Pa 120 100 150 130 180 200
Sound pressure level*** dB(A) 64 64 66 66 68 68
Net weight kg 90 100 150 160 180 200
Additional electric heater**** kW 2×3 2×4 2×5 2×6 2×6 2×8
Additional heating coil**** kW 22.2 28.4 35.1 40.0 46.0 53.3

 
Mod   52 62 72 88 104
Nominal cooling capacity* kW 51.3 63.3 71.3 87.9 103.7
Nominal heating capacity** kW 58.9 72.6 81.9 100.0 115.8
Connection            
Method / Welding Welding Welding Welding Welding
Liquid pipe diameter ¢mm 15.88/12.7 15.88×2 15.88×2 15.88×2 19.05×2
Gas pipe diameter ¢mm 28/19.05 28×2 28×2 28×2 35×2
Power supply / 230V/3N/60Hz
OUTDOOR UNIT Compressor  
Qty/refrigerant circuit Nr. 2/2 2/2 2/2 2/2 2/2
Cooling power input* kW 18.4 23.1 26.6 28.1 39.3
Heating power input** kW 18.22 22.87 26.33 27.82 38.91
Energy adjustment % 30-70-100 50-100 50-100 50-100 50-100
Axial fans  
Quantity Nr. 2 2 2 2 2
Airflow m3/h 21500 26500 29880 36500 43500
Sound pressure level*** dB(A) 71 71 71 71 71
Net weight kg 330 460 460 780 800
INDOOR UNIT Centrifugal fans            
Quantity Nr. 2 2 2 2 2
Airflow m3/h 9250 11450 12900 14800 17100
ESP Pa 200 300 300 280 500
Sound pressure level*** dB(A) 68 68 69 69 70
Net weight kg 220 230 300 320 400
Additional electric heater**** kW 2×8 2×10 2×10 2×12 2×14
Additional heating coil**** kW 57.8 71.2 80.3 98.0 113.5

Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
**** Optional as request.