• 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
  • 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
  • 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
  • 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
  • 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
  • 55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Type: Central Air Conditioners
Capacity: 8 Kw - 50kw
Usage: Room
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump pictures & photos
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
US $1,360-5,980 / Piece
Min. Order: 1 Piece
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW
Indoor Machine Noise
36-49dB
Certification
CE
China Energy Efficiency Standard
Level 3
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Refrigerant
R410A/R407c/R134A/R22/R404A
Compressor Brand
Panasonic/Copeland
Compressor Type
Scroll Type
Condenser
Blue Aluminum Fin
Evaporator
High Efficiency Tank Type
Heat Recovery
Optional
Electric Parts
World Famous Brand
Refrigerant Valves
Emerson
Running Condition
-30 Degree C
Colour
White(Standard) or Others
Transport Package
Plywood Package Unit
Specification
10-20
Trademark
Amrta or OEM
Origin
China
HS Code
8418612090
Production Capacity
6000PCS/Year

Packaging & Delivery

Package Size
1113.00cm * 594.00cm * 977.00cm
Package Gross Weight
120.000kg

Product Description

55~60C Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Heating Capacity 10 kW ~ 20 kW
Product features

Compressor
DC inverter type compressor
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

EVI technology
Enhanced vapor injection technology, heat pump can work -30oC ambient temperature
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Refrigerant
R410A refrigerant, more environmental

Stable and reliable
Simulation optimization + test verification, more stable and reliable
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Compact design
Use tank type heat exchanger
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Low noise fan

For lower ambient temp working
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
 
Professional control, more reliable, adaptive control for EXV
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
 
Heat exchanger design
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
 
More safety
Over 7 protections
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
 
Reliable EXV
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
Specifications

Model AW10 AW14 AW17 AW20
Ambient temperature DB/WB Hot water
Capacity

Unit

Packaged type
7oC/6oC 41oC Heating kW 11.2 18.9 19.8 20.7
Power input kW 3.1 5.4 5.8 6.4
-12oC/-14oC 41oC Heating kW 7 11.9 12.9 13.9
Power input kW 2.95 4.9 5.2 5.6
-20oC/--oC 41oC Heating kW 5.9 9.6 10.7 11.2
Power input kW 2.9 4.6 5.3 5.5
35oC/--- 7oC Cooling kW 8.7 12.5 13.5 14.9
Power input kW 3.0 4.4 4.8 5.6
Standard heating COP/IPLV W/W 2.37/2.83 2.43/2.86 2.48/2.87 2.48/2.88
Max power input kW 5.5 8.5 8.5 8.5
Max working current A 20 40 40 40
Compressor type/Brand DC inverter type/Highly
Compressor quantity 1
Fan Low Noise axial type
Fan quantity 1 2 2 2
Heat exchanger Tank type
Inlet/outlet water pipe size G1 G1 G1 G1
Water flow rate m3/h 1.5 2.14 2.32 2.56
Water resistance kPa 22 42 49 57
Refrigerant Type R410A
Charge amount kg 4 5 5 5
Min/Max Ambient temp Cooling oC 21-43
Heating oC -30-21
Min/Max Hot water Cooling oC 7-24
Heating oC 25-60
Min/Max working water pressure MPa 0.05-1
Power supply 220V/1/50Hz
Dimension(L×W×H) mm 1113x594x977 1113x594x1477
Noise level dB(A) 64 66 66 66
Net weight kg 120 160


Our Product Range

55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump


Production Process

55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump


Some Simple Overseas Projects

55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump

Contact Us
 
 





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump pictures & photos
55~60c Water Outlet DC Inverter Evi Air to Water Package Air Source Heat Pump
US $1,360-5,980 / Piece
Min. Order: 1 Piece
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes