10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

Product Details
Customization: Available
Type: Air Conditioner, Rooftop Packaged Unit, Chiller, Chiller, Rooftop Packaged Unit, Fan Coil Unit
Capacity: 5kw~1000kw, 8 Kw - 50kw
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
  • 10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
Find Similar Products

Basic Info.

Model NO.
AW
Indoor Machine Noise
Low, 36-49dB
Certification
CE, CCC, ISO, CE, CCC, CE
China Energy Efficiency Standard
Level 1, Level 3
Cooling/Heating
Cooling/Heating, Cooling/Heating
Power Source
Electrical, Electrical
Power Type
AC or DC, AC
Condition
New, New
Corrosion Durability
Higher
Noise Level
Low
Lifetime
>20 Years
Air Tube Material
Based on Project
Operating Voltage
220~240V, 380~415V, 460~480V etc
Application Fields
Industrial
Mounting
Ground, Rooftop, Ceiling etc
Refrigerant
R410A/R407c/R134A/R22/R404A
Compressor Brand
Copeland
Compressor Type
Scroll Type
Condenser
Blue Aluminum Fin
Evaporator
High Efficiency Tank Type
Heat Recovery
Optional
Electric Parts
World Famours Brand
Refrigerant Valves
Emerson
Running Condition
-30 Degree C
Colour
White(Standard) or Others
Transport Package
Plywood Package Unit
Specification
10-20
Trademark
Amrta or OEM
Origin
China
HS Code
8418612090
Production Capacity
6000PCS/Year

Packaging & Delivery

Package Size
1000.00cm * 560.00cm * 1316.00cm
Package Gross Weight
145.000kg

Product Description

-25 ~ 46degreec DC Inverter Evi Low Temperature Air Source Heat Pump with CE

Heating Capacity 10 kW ~ 20 kW
Product features

Compressor
DC inverter type compressor
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

EVI technology
Enhanced vapor injection technology, heat pump can work -30oC ambient temperature
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

Refrigerant
R410A refrigerant, more environmental

Stable and reliable
Simulation optimization + test verification, more stable and reliable
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

Compact design
Use tank type heat exchanger
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

Low noise fan

For lower ambient temp working
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
 
Professional control, more reliable, adaptive control for EXV
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
 
Heat exchanger design
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
 
More safety
Over 7 protections
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
 
Reliable EXV
10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating
Specifications

Model AW10 AW14 AW17 AW20
Ambient temperature DB/WB Hot water
Capacity

Unit

Packaged type
7oC/6oC 41oC Heating kW 11.2 18.9 19.8 20.7
Power input kW 3.1 5.4 5.8 6.4
-12oC/-14oC 41oC Heating kW 7 11.9 12.9 13.9
Power input kW 2.95 4.9 5.2 5.6
-20oC/--oC 41oC Heating kW 5.9 9.6 10.7 11.2
Power input kW 2.9 4.6 5.3 5.5
35oC/--- 7oC Cooling kW 8.7 12.5 13.5 14.9
Power input kW 3.0 4.4 4.8 5.6
Standard heating COP/IPLV W/W 2.37/2.83 2.43/2.86 2.48/2.87 2.48/2.88
Max power input kW 5.5 8.5 8.5 8.5
Max working current A 20 40 40 40
Compressor type/Brand DC inverter type/Highly
Compressor quantity 1
Fan Low Noise axial type
Fan quantity 1 2 2 2
Heat exchanger Tank type
Inlet/outlet water pipe size G1 G1 G1 G1
Water flow rate m3/h 1.5 2.14 2.32 2.56
Water resistance kPa 22 42 49 57
Refrigerant Type R410A
Charge amount kg 4 5 5 5
Min/Max Ambient temp Cooling oC 21-43
Heating oC -30-21
Min/Max Hot water Cooling oC 7-24
Heating oC 25-60
Min/Max working water pressure MPa 0.05-1
Power supply 220V/1/50Hz
Dimension(L×W×H) mm 1113x594x977 1113x594x1477
Noise level dB(A) 64 66 66 66
Net weight kg 120 160


Our Product Range

10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating


Production Process

10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating


Some Simple Overseas Projects

10kw 15kw 20kw Air Source Heat Pump -25 Degrees Heating

Contact Us
 
 





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier