Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
  • Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
FCU
Corrosion Durability
General
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Factory, Hospital, School, Supermarket and So on
Mounting
Ceiling Mount
Lifetime
1-2 Year
Certification
CE
Condition
New
Fan Quantity
1 or 2
Air Flow
1360m3/H-4080m3/H
Cooling
7.8-22.5kw
Transport Package
Plywood Casing
Specification
Color: white
Trademark
AMRTA or OEM
Origin
China
HS Code
8415830000
Production Capacity
10000PCS/Year

Packaging & Delivery

Package Size
725.00cm * 626.00cm * 329.00cm
Package Gross Weight
35.000kg

Product Description


Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit

Air flow: 1020m3/h-4080m3/h
Cooling: 5.17-22.5kW

 
Product Description

Efficient and energy saving
Efficient ABS blower which is light weighted while statically and dynamically balanced.

Excellent thinwall copper tube and efficient hydrophilic aluminum fin are under water pressure bonded treatment. Patent inverse crossing circuit to reach the best heat transfer efficiency. Brass water distributor is used for improving water flow distribution, in order to provide better heat transfer effect.

Quiet operation
Low noise and permanent capacity motor, unique ABS centrifugal blower, all of them pass dynamically balance test, to ensure unit operate quietly and efficiently.

3-speed motor, ball bearing, long lifespan; rubber vibration isolator reduces operation noise.

Stable and reliable
U-shaped tube bending, reducing soldered dot and leakage point.
Drain pan is made of high grade stainless steel plate, modeling processing; surface has been under hot dipped electroforming painting treatment. 7mm PE thermal insulation foam is applied on the drain pan to prevent condensation and leakage from occurring.

Furthermore the width and length of the drain pan has been specifically designed to accommodate the water drop from the water inlet/outlet and electrically operated valve.There is fuse in power supply inlet side to prevent motor burned because of wrong wiring. Reliable and stable motor which enjoys good reputation in the market.

Different models
• Static pressure: 12Pa, 30Pa, 50Pa.
• Fan coil unit series: horizontal exposed type, horizontal concealed type, vertical concealed type, vertical exposed type, cassette type, large air volume FCU.
• Accessories: 3-speed switch, return air box, extended drain pan, electronic two-way valve, electrical heater, air cleansing module.
All above are for your selection.

Detailed Photos


Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit

Product Parameters
Concealed Type Fan Coil Unit -2Pipes 3Rows 
Model FCU102 FCU136 FCU170 FCU204 FCU238 FCU272 FCU306 FCU340
Air flow) H m3/h 1020 1360  1700  2040  2380  2720  3060  3400 
M 765 1020  1275  1530  1785  2040  2295  2550 
L 561 748  935  1122  1309  1496  1683  1870 
Cooling capacity H W 5.17  6.89  8.61  10.34  12.06  13.78  15.50  17.23 
M 4.08  5.44  6.80  8.16  9.53  10.89  12.25  13.61 
L 3.10  4.13  5.17  6.20  7.23  8.27  9.30  10.34 
Heating capacity H W 8.61  11.49  14.36  17.23  20.10  22.97  25.84  28.71 
M 6.55  8.73  10.91  13.09  15.28  17.46  19.64  21.82 
L 5.00  6.66  8.33  9.99  11.66  13.32  14.99  16.65 
Fan Type / Centrifugal fan
Qty / 1
Motor Power supply V/Ph/Hz   220V~50Hz
Qty / 1 1 1 1 1 1 1 2
Power input W 270 300 350 405 454 585 730 785
Heat exchanger Type /   Aluminium fin + inner threaded copper tube
Max running pressure Mpa 1.6 Mpa
Rows / 3
Water inlet/outlet pipe /   DN25
Condensing water pipe /   DN20
Water flow M3/h 0.89  1.19  1.48  1.78  2.07  2.37  2.67  2.96 
Water resistance kPa 23 23.5 36 35 42 31 39 43
Sound pressure level dB(A) 52 53 55 57 58 60 61 61
Weight kG 35 36 38 45 50 61 77 81
Note:Note:
1. Cooling: DB/WB temp 27/19.5
ºC, water inlet temp 7ºC.
2. Heating: DB temp 21
ºC, water inlet temp  60ºC, hot water flow same as cooling condition.
 
Concealed Type Fan Coil Unit -2Pipes 4Rows 
Model FCU102 FCU136 FCU170 FCU204 FCU238 FCU272 FCU306 FCU340
Air flow) H m3/h 1020 1360  1700  2040  2380  2720  3060  3400 
M 765 1020  1275  1530  1785  2040  2295  2550 
L 561 748  935  1122  1309  1496  1683  1870 
Cooling capacity H W 6.26  8.34  10.43  12.52  14.60  16.69  18.78  20.86 
M 4.94  6.59  8.24  9.89  11.54  13.18  14.83  16.48 
L 3.76  5.01  6.26  7.51  8.76  10.01  11.27  12.52 
Heating capacity H W 10.43  13.91  17.39  20.87  24.34  27.82  31.30  34.78 
M 7.93  10.57  13.21  15.86  18.50  21.14  23.79  26.43 
L 6.05  8.07  10.08  12.10  14.12  16.14  18.15  20.17 
Fan Type / Centrifugal fan
Qty / 1
Motor Power supply V/Ph/Hz   220V~50Hz
Qty / 1 1 1 1 1 1 1 2
Power input W 270 300 350 405 454 585 730 785
Heat exchanger Type /   Aluminium fin + inner threaded copper tube
Max running pressure Mpa 1.6 Mpa
Rows / 4 4 4 4 4 4 4 4
Water inlet/outlet pipe /   DN25
Condensing water pipe /   DN20
Water flow M3/h 1.08  1.44  1.79  2.15  2.51  2.87  3.23  3.59 
Water resistance kPa 23.5 24 37 40 50 30 38 42
Sound pressure level dB(A) 52 53 55 57 58 60 61 61
Weight kG 39 40 42 49 55 66 80 84
Note:
1. Cooling: DB/WB temp 27/19.5
ºC, water inlet temp 7ºC.
2. Heating: DB temp 21
ºC, water inlet temp  60ºC, hot water flow same as cooling condition.
 
Concealed Type Fan Coil Unit -4Pipes 3+1Rows 
Model FCU102 FCU136 FCU170 FCU204 FCU238 FCU272 FCU306 FCU340
Air flow H m3/h 1020 1360  1700  2040  2380  2720  3060  3400 
M 765 1020  1275  1530  1785  2040  2295  2550 
L 561 748  935  1122  1309  1496  1683  1870 
Cooling capacity H W 5.17  6.89  8.61  10.34  12.06  13.78  15.50  17.23 
M 4.08  5.44  6.80  8.16  9.53  10.89  12.25  13.61 
L 3.10  4.13  5.17  6.20  7.23  8.27  9.30  10.34 
Heating capacity H W 4.27  5.70  7.12  8.55  9.97  11.40  12.82  14.25 
M 3.25  4.33  5.41  6.50  7.58  8.66  9.75  10.83 
L 2.48  3.31  4.13  4.96  5.79  6.61  7.44  8.26 
Fan Type / Centrifugal fan
Qty / 1
Motor Power supply V/Ph/Hz   220V~50Hz
Qty / 1 1 1 1 1 1 1 2
Power input W 270 300 350 405 454 585 730 785
Heat exchanger Type /   Aluminium fin + inner threaded copper tube
Max running pressure Mpa 1.6 Mpa
Rows / 3+1 3+1 3+1 3+1 3+1 3+1 3+1 3+1
Water inlet/outlet pipe in cooling / DN25
Water inlet/outlet pipe in heating / DN20
Water flow Condensing water pipe / DN20
Water flow in cooling m3/h 0.89  1.19  1.48  1.78  2.07  2.37  2.67  2.96 
Water resistance in cooling kPa 23 23.5 36 35 42 31 39 43
Water flow in heating m3/h 0.37  0.49  0.61  0.74  0.86  0.98  1.10  1.23 
Water resistance in heating kPa 9.89 10.62 16 27.32 32.43 22.22 27.59 30.07
Sound pressure level dB(A) 52 53 55 57 58 60 61 61
Weight kG 35 36 38 45 50 61 77 81
Note:Note:
1. Cooling: DB/WB temp 27/19.5
ºC, water inlet temp 7ºC.
2. Heating: DB temp 21
ºC, water inlet temp  60ºC, hot water flow same as cooling condition.
 
Certifications

 

Packaging & Shipping

 

Company Profile

Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil UnitCommercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil UnitCommercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil UnitCommercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil UnitCommercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil UnitCommercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
Project

Commercial Horizontal Concealed Chilled Water Large Air Flow Big Fan Coil Unit
 






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier