Low Ambient in Winter Heating Hot Water Chiller Air Conditioner

Product Details
Customization: Available
Type: Central Air Conditioners
Usage: Room
Still deciding? Get samples of US$ 1405/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
  • Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
Find Similar Products

Basic Info.

Model NO.
ASHP-( )L
Indoor Machine Noise
<23dB
Certification
CE
China Energy Efficiency Standard
Level 1
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Refrigerant
R140A/R32/R290
Compressor
Rotary/Scroll
Condensing Fan
Axial, Plastic Fan Blade
Heat Exchanger
High Efficiency Tank Type
Power Supply
1n~220V 50Hz
Transport Package
Carton Packing
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
6000PCS/Year

Packaging & Delivery

Package Size
1600.00cm * 450.00cm * 1080.00cm
Package Gross Weight
220.000kg

Product Description

Low Ambient in Winter Heating Hot Water Chiller Air Conditioner
Low Ambient in Winter Heating Hot Water Chiller Air Conditioner


Characteristics

Low ambient and high efficiency
Lowest ambient for heating -25ºC, COP is higher than 1.62 when hot water inlet/outlet is 50ºC/55ºC, and highest outlet temp. is 60ºC.

Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

Compressor
Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators

Axial fan
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, plastic blade for low noise.

Evaporator
High efficiency tank type heat exchanger, factory insulated with flexible close cell material. 

Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, protected with flexible plastic grill. 

Refrigerant cicuit
Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, electronic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset.
The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.

Water cicuit
Without water pump and expansion tank, but with paddle flow switch.

Electric panel
consists of:  
Compressor contactor;
Compressor protection breaker;
Fan motor protection breaker;
Control circuit protection breaker;
Programmable microprocessor controller
Low Ambient in Winter Heating Hot Water Chiller Air Conditioner


Technical Data
 
 Item                                                                                               Model ASHP-10L ASHP-15L ASHP-20L
DB/WB IN/OUT water Capacity Unit
7ºC/6ºC 36ºC/41ºC Heating kW 9.6 14.5 19.1
Power input kW 2.5 3.8 5.1
50ºC/60ºC Heating kW 9.8 14.5 19.8
Power input kW 3.3 4.8 6.5
-12ºC/-14ºC 36ºC/41ºC Heating kW 6.1 9.2 11.8
Power input kW 2.32 3.70 4.70
50ºC/60ºC Heating kW 6.6 9.8 12.8
Power input kW 3.2 4.8 6.4
-20ºC/-ºC 36ºC/41ºC Heating kW 5.2 7.7 10.3
Power input kW 2.30 3.60 4.60
50ºC/55ºC Heating kW 5.4 8.1 10.8
Power input kW 2.9 4.3 5.8
-25ºC/-ºC 36ºC/41ºC Heating kW 4.5 6.0 8.9
Power input kW 2.40 3.40 4.80
50ºC/55ºC Heating kW 4.7 6.8 9.5
Power input kW 2.9 4.5 5.9
35ºC/--- 12ºC/7ºC Cooling kW 7.2 10.2 14.2
Power input kW 2.7 3.7 5.2
Compressor Type   Scroll Scroll Scroll
Qty   1 1 1
Control methods   Electronic expansion valve
Condensing fan Type   Axial, plastic fan blade Axial, plastic fan blade Axial, plastic fan blade
Qty   1 2 2
Power input w 90 90 90
Max power input kW 4.1 5.8 8.2
Max working current A 18 29 36
Pipe size R1'' R1'' R1''
Evaporator type   High efficiency tank type heat exchanger
Water flow Cooling (△5k) m3/h 1.24 1.75 2.4
Heating (△5k/△10k) m3/h 1.58/0.79 2.49/1.25 2.9/1.45
Water resistance kPa 40 45 46
Refrigerant Type   R410A
Charge amount kg 3.6 5.3 6.1
Working range ºC -25ºC-46ºC
Power supply 1N~220V 50Hz
Dimension mm 1200x560x858 1000x560x1316 1100x620x1316
Noise level dB(A) 54 56 56
Weight kg 122 150 170

Note: Without water pump and expansion tank, but with paddle flow switch

Why Choose Amrta?
Low Ambient in Winter Heating Hot Water Chiller Air Conditioner

Ordering Process
Low Ambient in Winter Heating Hot Water Chiller Air Conditioner

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier