Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller

Product Details
Customization: Available
Cooling Method: Indirect Cooling
Certification: CE
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
  • Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
Find Similar Products

Basic Info.

Model NO.
FCU
Type
2pipes 3rows
Type 1
4pipes 3+1rows
Installation Type
Cassette / Concealed / Exposed
Motor
DC / Ec Motor(Optional)
Transport Package
Carton Packing
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
10000PCS/Year

Packaging & Delivery

Package Size
1090.00cm * 610.00cm * 260.00cm
Package Gross Weight
25.000kg
Lead Time
10 days (1 - 500 Pieces)
To be negotiated ( > 500 Pieces)

Product Description

Concealed Ceiling / Casette Type Water Chiller Fan Coil Unit Central Air Conditioner with Bacnet Thermostat

Air Flow 340 m3/h ~ 6800 m3/h

Our Products Range

Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller


Characteristics
Efficient and energy saving
Efficient ABS blower which is light weighted while statically and dynamically balanced.

Excellent thinwall copper tube and efficient hydrophilic aluminum fin are under water pressure bonded treatment. Patent inverse crossing circuit to reach the best heat transfer efficiency. Brass water distributor is used for improving water flow distribution, in order to provide better heat transfer effect. 

Quiet Operation
Low noise and permanent capacity motor, unique ABS centrifugal blower, all of them pass dynamically balance test, to ensure unit operate quietly and efficiently.

3-speed motor, ball bearing, long lifespan; rubber vibration isolator reduces operation noise.

Stable and Reliable
U-shaped tube bending, reducing soldered dot and leakage point.  
Drain pan is made of high grade stainless steel plate, modeling processing; surface has been under hot dipped electroforming painting treatment. 7mm PE thermal insulation foam is applied on the drain pan to prevent condensation and leakage from occurring. Furthermore the width and length of the drain pan has been specifically designed to accommodate the water drop from the water inlet/outlet and electrically operated valve.There is fuse in power supply inlet side to prevent motor burned because of wrong wiring. Reliable and stable motor which enjoys good reputation in the market.

Different Models

Static pressure: 12Pa, 30Pa, 50Pa.
Fan coil unit series: horizontal exposed type, horizontal concealed type, vertical concealed type, vertical exposed type, cassette type, large air volume FCU.
Accessories: 3-speed switch, return air box, extended drain pan, electronic two-way valve, electrical heater, air cleansing module.
All above are for your selection.

Performance Parameter

2pipes 3rows
Model                      FCU 34 51 68 85 102 136 170 204 238
Air flow H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M m3/h 255 383 510 638 765 1020 1275 1530 1785
L m3/h 170 255 340 425 510 680 850 1020 1190
Total cooling capacity * H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1440 2160 2880 3600 4320 5760 7200 8640 10080
L W 1170 1755 2340 2925 3510 4680 5850 7020 8190
Sensible cooling capacity* H m3/h 1307 1961 2615 3268 3922 5229 6537 7844 10300
M m3/h 1177 1765 2353 2942 3530 4706 5883 7060 8500
L m3/h 1059 1588 2118 2647 3177 4236 5295 6354 7460
Heating capacity* H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W 2160 3240 4320 5400 6480 8640 10800 12960 15120
L W 1857 2633 3510 4388 5265 7020 8775 10530 11340
Standard external pressure Pa 12 12 12 12 12 12 12 12 12
Power input 12Pa W 35.2 46 57.4 69 86 123 160 189 228
30Pa W 39.5 55 66.9 82 100 136 175 211 247
50Pa W 49.5 59 85.4 93 108 155 188 236 297
Sound pressure Level** 12Pa dB(A) 37 39 41 43 45 46 48 50 52
30Pa dB(A) 40 42 44 46 47 48 50 52 54
50Pa dB(A) 42 44 46 47 49 50 52 54 56
Net weight kg 10.5 14.6 16 16.5 18.5 23.5 25.5 30.5 35.5
Water flow rate m3/h 0.4 0.51 0.71 0.92 1.05 1.4 1.75 2.1 2.5
Water pressure drop kPa 20 20 25 30 35 40 40 45 50
Water connections Inch RC 3/4
Drain pipe Inch RC 3/4
Fan motor quantity Nr. 1 1 1 1 1 2 2 2 2
Fan quantity Nr. 1 2 2 2 2 3 4 4 4
Max. working pressure Mpa 2
Power supply / 220V/1Ph/50Hz

4pipes 3+1rows
Model                    FCU 34 51 68 85 102 136 170 204 238
Air flow H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M m3/h 255 383 510 638 765 1020 1275 1530 1785
L m3/h 170 255 340 425 510 680 850 1020 1190
Total cooling capacity * H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1440 2160 2880 3600 4320 5760 7200 8640 10080
L W 1170 1755 2340 2925 3510 4680 5850 7020 8190
Sensible cooling capacity* H m3/h 1307 1961 2615 3268 3922 5229 6537 7844 10300
M m3/h 1177 1765 2353 2942 3530 4706 5883 7060 8500
L m3/h 1059 1588 2118 2647 3177 4236 5295 6354 7460
Heating capacity* H W 810 1215 1620 2025 2430 3240 4050 4860 6300
M W 729 1094 1458 1823 2187 2916 2645 4374 5040
L W 656 984 1312 1640 1968 2624 3281 3937 3780
Standard external pressure Pa 12 12 12 12 12 12 12 12 12
Power input 12Pa W 35.2 46 57.4 69 86 123 160 189 228
30Pa W 39.5 55 66.9 82 100 136 175 211 247
50Pa W 49.5 59 85.4 93 108 155 188 236 297
Sound pressure Level** 12Pa dB(A) 37 39 41 43 45 46 48 50 52
30Pa dB(A) 40 42 44 46 47 48 50 52 54
50Pa dB(A) 42 44 46 47 49 50 52 54 56
Net weight kg 10.5 14.6 16 16.5 18.5 23.5 25.5 30.5 35.5
Water flow rate m3/h 0.4 0.51 0.71 0.92 1.05 1.4 1.75 2.1 2.5
Water pressure drop kPa 20 20 25 30 35 40 40 45 50
Water connections Inch RC 3/4
Drain pipe Inch RC 3/4
Fan motor quantity Nr. 1 1 1 1 1 2 2 2 2
Fan quantity Nr. 1 2 2 2 2 3 4 4 4
Max. working pressure Mpa 2
Power supply / 220V/1Ph/50Hz
*The data are referred to the following conditions:
Cooling: room temperature: 27°C 50% RH, water temperature: 7/12°C, high speed.
Heating: room temperature: 21°C, water temperature: 45/40°C, high speed.
 
Production Process

Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller

Unit Pictures


Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for ChillerHorizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for ChillerHorizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for ChillerHorizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller
Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller





Our Factory and Certificates

Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller

Some Simple Overseas Projects

Horizontal Concealed Ceiling Exposed Cassette Chilled Water Fan Coil Unit for Chiller





 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier