Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Still deciding? Get samples of US$ 1260/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
  • Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
Find Similar Products

Basic Info.

Model NO.
RTU( )
Type
Central Air Conditioner
System Type
Closed System
Noise Level
Ultra Low
Application Fields
Apartment, Villa, University, Library, Hospital
Certification
CE
Condition
New
Cooling Capacity
10kw-260kw
Refrigerant
R410A/R290/R32/R134A
Compressor
Scroll Type
Gas Burner
Optional
Fresh Air
Optional
Free Cooling
Optional
Proof Explosion
Optional
Heat Recovery
Optional
Power Supply
50Hz/60Hz
Transport Package
Plywood Package or Plastic Film Wrapped
Trademark
AMRTA or OEM
Origin
China
HS Code
8418612090
Production Capacity
6000PCS/Year

Product Description

Rooftop Packaged Air Conditioner with Free Cooling 
Rooftop packaged unit with free cooling which integrates condensing part, evaporating part & control part into a whole unit, firstly promoted & applied in South America, North Europe & Australia. It is air cooled direct evaporation & expansion air conditioner, has no need on cooling water & chilled water systemdispenses with cooling tower/cooling water pump/chilled water pump,  relative pipe work, electric control & terminal equipments, saves user investment. It integrates evaporating part & condensing part into a whole unit which is installed outside to save indoor space, user will only need to install the duct, no need to connect refrigerant pipe work, it works under intellectual control without special care. Rooftop packaged unit is mainly applied to factories, schools, auditoriums, warehouses, etc.



Characteristics
Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Direct expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
Centrifugal fan
Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
Front, side and underside air discharge of the treatment unit.
High external pressure, long air supply distance.
Electric panel
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
Easy operation line controller
Cooling/Heating/Auto
Error indication
Timing on/off
Optional
Economizer with fresh, return air dampers and fresh air hood
Free cooling function for low ambient temperature
Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
100% heat recovery
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply/return air configurations
Upgraded plug fan
G4 filter, plate and bag filter

Economizer and Free Cooling
Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling


It is one of the most important features of this rooftop as it maximise seasonal efficiency by reducing the use of thermodynamic cooling in mid season.
Thermodynamic cooling can be replaced by Free Cooling when outdoor temperature is below the building set point saving up to 15% on annual energy consumption.
Rooftop units are supplied with economizer and fresh air hood to improve comfort through better fresh air management and allow energy savings with free cooling.
Exhaust air
Gravity exhaust damper
Gravity exhaust damper Installed with economizer assembly, gravity exhaust damper relief pressure when outside air is being introduced in the system. It is a cheap and smart way to avoid over pressure in a building.
Power exhaust fans
Installed with economizer assembly, it provides exhaust air pressure relief when high levels of fresh air are being introduced in the system.
Interlocked to run when return air dampers are being closed and supply air blower is in operation. The extraction fans run when outdoor air dampers are at least 50% open (adjustable). It is also overload protected. A gravity exhaust damper is supplied with this option to prevent air from entering the unit during shutdown. The power exhaust fans have been size to exhaust 50% of the nominal air flow of the unit.


Technical Data
 
Model  RTU45 RTU50 RTU60 RTU75 RTU90 RTU105
Cooling capacity kW 44.5 50 60 70 90 105
Heating capacity kW 48.7 54.3 64 75.4 96.2 113.2
Power supply   380V / 3Ph / 50HZA
Cooling power input kW 17 19.5 22.8 26.7 32.9 39.7
Heating power input kW 15.6 18 21 24.8 30.4 36.7
Start current A 168 186 175 199 197 266
Working current in cooling A 31.7 35.6 39.9 48.3 61 70.6
Working current in heating A 29.9 33.5 37.5 45.4 57.3 66.3
Throttle methods Thermal expansion valve
Circuits 2 2 2 2 3 3
Refrigerant R410A
Compressor Type Scroll type        380V / 3Ph / 50HZA
Qty 2 2 2 2 3 3
Condenser side
Condenser Type Al+copper tube
Axial fan Qty 1 1 1 1 2 2
Drive Direct drive
Motor power kW 0.25 0.37 0.37 0.55 0.75 0.75
Air flow m/h 4600 7800 7800 9000 12600 12600
Evaporator side
Evaporator Type Al+copper tube
Centrifugal fan Qty 1 1 1 1 1 1
Motor power kW 3 3 4 4 5.5 5.5
Air flow m/h 7600 8500 10900 12500 16000 19500
Drive Direct drive Belt drive
External static pressure(Pa) 250 250 300 300 300 300
Filter Aluminum frame filter G3
Noise level dB(A) 73 73 73 75 74 75
Dimension L mm 2268 2268 2298 2298 2878 2878
W mm 1440 1440 1650 1650 2140 2270
H mm 1167 1167 1400 1400 1964 1964
Weight kg 750 770 830 860 1160 1350
* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.

Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling
Direct Expansion Rooftop Packaged Air Conditioner with Free Cooling

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier